 How to Direct-Wire Dual-Ended LED Tube Lights 2 Lamps

Replace

Ballasts

Replace 1

Lamp Series Ballast with 2 lamp Parallel

Replace 1 Lamp Series Ballast with 2 Lamp Series

Replace 2

Lamp Parallel Ballast

Replace 2

Lamp Series Ballast with Parallel

Replace 2

Lamp Series Ballast with Parallel 2

Replace 2

Lamp Series Ballast with Series

Replace 3

Lamp Parallel Ballast

Replace 3 Lamp Two Parallel Ballasts with Parallel

Replace 3

Lamp Series Ballast with Parallel

Replace 3 Lamp Two Series Ballasts with Parallel

Replace 3

Lamp Series-Parallel

Ballast with Parallel

Replace 3

Lamp Series-Parallel

Ballast with Parallel 2

Replace 3

Lamp Series-Parallel

Ballast with Series

Replace 4

Lamp Parallel Ballast

Replace 4 Lamp Two Series Ballasts with Parallel

Replace 4

Lamp Series Ballast with Parallel

Replace Fluorescent Tubes with LED

Direct-Wire Dual-Ended

LED Tube

Lights

Direct-Wire Single-Ended LED Tube

Lights

For dual-ended direct-wired LEDs, line is connected to the lampholders at one end of the fixture, neutral at the other end. Shunted or non-shunted lampholders can be used with dual-ended LED tubes. Dual-ended tubes can be reversed in a light fixture just like a fluorescent tube. When using non-shunted lampholders, the wires only need to be connected to one side of the lampholder with most LED tubes (check the wiring instructions).

A fixture modification label is affixed to the fixture showing which end has power. This label should be supplied with the tube(s).

2 Lamp Led Dual-Ended Parallel Ballast Lampholder Wiring Diagram

2 Lamp Instant Start Ballast (Wired in Parallel)

Factory wiring

LED Direct-Wired Dual-Ended Wiring Diagram

For 2 lamp instant start fixture (ballast wired in parallel)

When line and neutral wires are 12 or 14 AWG size, use tan or yellow wire connectors

Individual lampholder wires (blue) are connected to line.

Common wires (red) are connected to neutral.

These connections can be reversed. Individual to neutral and common to line.

2 Lamp Two Rapid Start Ballasts (Wired in Series)

2 Lamp Series Ballast Lampholder Wiring DiagramFactory wiring


LED Direct-Wired Dual-Ended Wiring Diagram

For 2 lamp rapid start fixture (ballast wired in series)

2 Lamp Led Singlel-Ended Series Ballast Lampholder Wiring Diagram

When line and neutral wires are 12 or 14 AWG size, use tan or yellow wire connectors

Individual lampholder wires (blue and red) are connected to line.

Common wires (yellow) are connected to neutral.

These connections can be reversed. Individual to neutral and common to line.


2 Lamp Parallel Ballast Lampholder Wiring Diagram